Certificate

SGS Test Reports for MAISHI Drone Protection Netting

MAISHI nylon drone protection netting has been tested by SGS for tensile strength and for resistance to UV light ageing. The net reached a maximum force of 810 N transverse and 830 N lengthways under ISO 13934-1, and after 500 hours of accelerated UV exposure to ASTM G154 all specimens kept a grey scale rating of 4-5 with no other visual change, which supports long-term outdoor use in high-sun regions.

Verify every report with SGS. Each report below is issued to HEBEI MAISHI WIRE MESH MANUFACTURE CO., LTD. If a supplier shows you one of these reports under a different company name, the SGS record will reveal it. Report numbers and QR codes are left visible for this purpose.

Tensile Strength Test (ISO 13934-1)

Report No.SZIN2609002661PL02_EN (SGS Ref. GZMR260903392202)
SampleNylon Netting (Drone Protection Net), finished product
LaboratorySGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch
Issue date2026-09-28
Standard / methodISO 13934-1:2013 maximum force test, 100 mm/min, 200 mm grip separation, 5 mm specimen width, conditioned at (23 ± 2) °C and (50 ± 4) %RH
Key resultMaximum force: transverse 810 N, lengthways 830 N.
How to verifyScan the QR code on the cover page, or enter the report number at check.sgsonline.com.cn. You can also e-mail [email protected].
Full reportRequest the complete report No. SZIN2609002661PL02_EN
MAISHI drone protection netting SGS tensile test (ISO 13934-1) report No. SZIN2609002661PL02_EN - cover page
Cover page (watermarked preview)
MAISHI drone protection netting SGS tensile test (ISO 13934-1) report No. SZIN2609002661PL02_EN - results page
Results page (watermarked preview)

UV Light Ageing Test, 500 h (ASTM G154)

Report No.SZIN2609002661PL03_EN (SGS Ref. GZMR260903392201)
SampleNylon Netting (Drone Protection Net), nylon/polyester, finished product
LaboratorySGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch
Issue date2026-10-21
Standard / methodASTM G154-23 Cycle 1, UVA-340 lamps: 8 h light at 60 °C BPT, 0.89 W/(m²·nm) at 340 nm, then 4 h condensation at 50 °C BPT
Key resultAfter 500 h: grey scale 4-5 (scale 5 = best, ISO 105-A02) and no other visual change on 3 of 3 specimens.
How to verifyScan the QR code on the cover page, or enter the report number at check.sgsonline.com.cn. You can also e-mail [email protected].
Full reportRequest the complete report No. SZIN2609002661PL03_EN
MAISHI drone protection netting SGS UV ageing test (ASTM G154) report No. SZIN2609002661PL03_EN - cover page
Cover page (watermarked preview)
MAISHI drone protection netting SGS UV ageing test (ASTM G154) report No. SZIN2609002661PL03_EN - results page
Results page (watermarked preview)

Only the cover page and one results page of each report are shown online. The complete original report is sent on request after an inquiry, as a view-only link or as a PDF issued to your company name.

Request the full test report

Company Certificates and Earlier Test Reports

v20261027.02